GR Installations

GR Installations HETAS CERTIFICATED Solid fuel appliance and flue system installation. Period FIREPLACE & FIRE PIECE Restoration.

30/04/2026
Removal of old Gas fire (by Gas safe engineer)Open out chamber to original opening,managing to keep black tile backing.B...
16/04/2026

Removal of old Gas fire (by Gas safe engineer)
Open out chamber to original opening,managing to keep black tile backing.Black trim around chamber and keep original tiled hearth.
MI FIRES,Loughrigg 5kw wood burner 🔥

20 year old liner and stove upgrade.Old hearth tiles gone!Nice honed granite hearth,slips and header upgrade! Bassington...
10/04/2026

20 year old liner and stove upgrade.
Old hearth tiles gone!
Nice honed granite hearth,slips and header upgrade!
Bassington eco 5kw multi fuel stove,Personal favourite! 🔥

Job of previous post put right and now up running 🔥
05/04/2026

Job of previous post put right and now up running 🔥

This job was a bit of an eye opener!Customer had a flue system and multi fuel stove installed 20years ago (Not by me).Du...
05/04/2026

This job was a bit of an eye opener!
Customer had a flue system and multi fuel stove installed 20years ago (Not by me).
Due to its poor set up sweeping of the flue system was nearly impossible and no chimney sweep would touch it.
After meeting this client at another job I was servicing a stove on I agreed to take a look.
On inspection I noticed the the stove had black melted tar like puddles on the top of the stove that had dried.
This being not normal and being concerned with my clients safety in using the stove I had to condemn the installation as unsafe!
The client agreed on further inspections which included opening up the front of the chimney breast.
The photo show what I had found is that cavity wall insulation had been put in to the chimney itself! The cavity wall insulation was done on a government scheme about 10 years after the stove installation.
This was being melted by the heat of the solid fuel liner and dripping on to the stove through the closure plate.
This would have given of
Dangerous fumes!
Please be aware this can happen if the cavity wall insulation is installed by someone who is incompetent in making sure this does not happen!
A heads up if you have this type of wall insulation installed.

New Stone surround (Bellingham) with Honed granite hearth,Slips & Header.Also Replaced BAXI fire bricks.🔥
13/02/2026

New Stone surround (Bellingham) with Honed granite hearth,Slips & Header.
Also Replaced BAXI fire bricks.
🔥

Winter is here 🔥
05/01/2026

Winter is here 🔥

05/01/2026

Address

53 Leith Avenue
Portchester
PO168HN

Opening Hours

Monday 9am - 5pm
Tuesday 9am - 5pm
Wednesday 9am - 5pm
Thursday 9am - 5pm
Friday 9am - 5pm

Telephone

+447590895255

Alerts

Be the first to know and let us send you an email when GR Installations posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share

Category